HK DG4V3 22A VM U 12DC

4/2-Magnetventil NG6 12VDC
Product details for

HK DG4V3 22A VM U 12DC

Type
4/2
Nominal voltage/ current type
12 V DC
Piston type
22A [PB/A/T]-[PA/B/T]
Design
spring return

Characteristics

Max. working pressure
  • P, A, B: max. 350 bar / T: max. 210 bar 
Design
  • 4/2-way valve or 4/3-way valve 
  • with manual override function 
Connection
  • ISO/Cetop 03 size 6 
Flow rate
  • max. 80 l/min (note characteristic curves) 
Mounting
  • 4 pcs. hexagon socket screw M 5 x 30 12.9 
  • screw set HK M5 30 for 1 basic valve. In vertical stacking applications with intermediate plates, the use of the appropriate longer screws are required. 
Protection class
  • IP 65 
Customs tariff number
  • 84812010 
All characteristics

Descripción de productos

Notes
The O-rings (NBR 70 Shore A) for the valve port can be ordered as spare part separately under the following article number: 4 pieces OR9.25-1.78
Description
For switching capacity limits, see characteristic curves.
Ordering information
Further circuits and versions, volumetric flows and switching power limits are available on request
Delivery scope
With coil, without plug

Product variants

9 Results
Show dimensional drawing
Identifier
Type
Nominal voltage/ current type
Overlap
Piston type
4/2 
110 V AC 
positive (closed) 
2B [PB/AT]-[A/B/P/T] 
4/2 
230 V AC 50 Hz 
positive (closed) 
2B [PB/AT]-[A/B/P/T] 
4/2 
230 V AC 50 Hz 
positive (closed) 
6B [PB/AT]-[ABT/P] 
4/2 
110 V AC 
negative (open) 
8BL [PA/BT]-[A/B/PT] 
4/2 
12 V DC 
positive (closed) 
22A [PB/A/T]-[PA/B/T] 
4/2 
110 V AC 
positive (closed) 
22A [PB/A/T]-[PA/B/T] 
4/3 
12 V DC 
positive (closed) 
7C [PB/AT]-[PAB/T]-[PA/BT] 
4/2 
12 V DC 
positive (closed) 
2N [PB/AT]-[PA/BT] 
4/2 
230 V AC 50 Hz 
positive (closed) 
2N [PB/AT]-[PA/BT] 
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]

Column selection

Type
Nominal voltage/ current type
Overlap
Piston type
Design
Piston type example: [A/B/PT] = [A blocked / B blocked / P+T connected]